8/20/2012 12:19:32 AM
The magnetic separator is mainly composed of the base, the under magnetic system, the turn cage, the up magnetic system, the hollow shaft, the concentrate tank, the transmission devices and so on.
In the using process of magnetic separator, there will be some breakdowns. What are the common breakdowns of magnetic separator and how to solve those breakdowns? Now Hongxing Experts will tell you some common breakdowns and their solutions of magnetic separator.
1. The electrical machine of magnetic separator is overheated and its sound is not normal.
The reasons for the overheated electrical machine and abnormal sound are as follows.
(1) The bearing lubrication is undesirable or the bearing is in great attrition.
(2) The fan leaves are falling off or wearing.
(3) The switch line is in poor contact or disconnected.
(4) The voltage is too low.
2. The running sound of magnetic separator is abnormal.
The reasons for the abnormal running sound of magnetic separator are as follows.
(1) The cylinder is stuck by obstacles, which stops the rotation of cylinder and makes the bottom box vibrate.
(2) The magnet is falling off, which makes the barrel screak, even scratches the barrel skin. At this time, it is necessary to stop the magnetic separator for maintenance and troubleshooting.
3. The reduction box is overheated.
The reasons for the overheated reduction box are as follows.
(1) The quantity of oil is not enough or the quality of oil is not good enough.
(2) The wheel gear and worm wears off seriously or the engagement is not good enough.
(3) The bearing lubrication is undesirable or the bearing is in great attrition.
4. The magnetic field intensity of magnetic separator turns weak.
The reasons for the weak magnetic field intensity of magnetic separator are as follows.
(1) The temperature is too high.
(2) The sun exposure.
(3) The corrosion of acid and alkali, which can be metered by the Gauss Meter.